HPT Power-Limiting Heating Cable
HPT Power-Limiting Heating Cable

HPT Power-Limiting Heating Cable

HPT Power-Limiting Heating Cable Specification

  • Core Number
  • Single or double core.
  • Impedance
  • Specific impedance based on model (consult datasheet).
  • Armored Material
  • Optional galvanized steel or stainless steel armor.
  • Rated Temperature
  • Up to 250C (482F) depending on type.
  • Core Material
  • Tinned copper or nickel-plated copper.
  • Usage & Applications
  • Industrial, commercial, and residential heat tracing.
  • Dielectiric Strength
  • 2,500V to 3,500V (as per standard).
  • Locking Type
  • Clip or clamp based.
  • Weight
  • Varies with length and type.
  • Tensile Strength
  • High tensile strength as per specification.
  • Insulation
  • High temperature resistant polymer.
  • Number of Conductor
  • Two.
  • Conductor Shape
  • Stranded.
  • Operating Temperature
  • -40C to +250C (max exposure temp).
  • Install Type
  • Surface mounted, pipe-wrapped.
  • Conductor Type
  • Twin or parallel conductors.
  • Features
  • Self-regulating, power-limiting, freeze protection, suitable for hazardous locations, energy efficient, flexible design.
  • Diameter
  • 6 mm to 15 mm (depending on model).
  • Cable Type
  • Self-regulating heating cable (power-limiting).
  • Product Type
  • Power-limiting self-regulating heating cable.
  • Length
  • Customizable, supplied as per requirement.
  • Voltage
  • Typically 110V, 220V, or 240V (as per model specification).
  • Insulation Material
  • Fluoropolymer or modified polyolefin.
  • Application
  • Pipe trace heating, tank heating, roof and gutter de-icing, process temperature maintenance.
  • Conductor Material
  • Nickel-plated or tinned copper.
  • Jacket Material
  • Fluoropolymer, polyolefin, or thermoplastic.
  • Storage Temperature
  • -40C to +60C.
  • Connector Color
  • Varies by requirement, typically red or black.
  • Shield Material
  • Tinned copper braid.
  • Jacket Color
  • Dimension (L*W*H)
  • Varies depending on cable type and model.
  • Material
  • High-quality polymers and metallic conductors.
  • Color
  • Red standard, custom on request.
  • Size
  • Customizable (refer to datasheet).
  • Fire Resistance
  • Meets applicable international fire safety standards
  • Minimum Installation Temperature
  • -40C (-40F)
  • Bend Radius
  • Minimum 25 mm (as per cable size)
  • Maximum Exposure Temperature (Energized)
  • Up to 250C (482F)
  • Compliance Standards
  • IEEE 515, IEC 60079, UL 515, FM Approved
  • UV Resistance
  • High, suitable for outdoor installation
  • Heat Output
  • 10 to 65 W/m (as per model and voltage)
  • Moisture Resistance
  • Highly resistant to water ingress
  • Maximum Exposure Temperature (De-energized)
  • 260C (500F)
  • Chemical Resistance
  • Resistant to acids, alkalis, oils, and solvents
  • Explosion Proof
  • Yes, suitable for hazardous areas
 

HPT Power-Limiting Heating Cable Trade Information

  • Minimum Order Quantity
  • 5 Meter
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10 Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About HPT Power-Limiting Heating Cable



Explore a transcendent thermal management solution with the HPT Power-Limiting Heating Cable. This hot deal merges noble engineering with triumphant safety, delivering customizable heating lengths for diverse applications-including hazardous and outdoor environments. Engineered for ephemeral weather extremes, its high UV, moisture, chemical, and fire resistance guarantees resilient performance. This cable's flexible, self-regulating design ensures exceptional efficiency, while robust compliance and explosion-proof features inspire confidence in every installation. Elevate your process with a heating solution as dynamic and enduring as your ambition.

Precision Plant Heating for Critical Applications

The HPT Power-Limiting Heating Cable effortlessly adapts to various industrial plant requirements. Its application spans pipe tracing, tank heating, roof and gutter de-icing, as well as process temperature maintenance. This cable excels on metal or plastic surfaces and resists exposure to water, chemicals, and UV radiation. Whether used in harsh outdoor environments or complex processing facilities, its performance remains triumphant, protecting diverse media such as water, oil, acids, and solvents against freezing and temperature fluctuations.


Order Completion and Market Readiness

Serving as your noble supplier and trader for India's main domestic market, we ensure seamless order completion. Your cables reach you efficiently-whether by scheduled drop-off or secure shipping, each package is carefully handed over to preserve product integrity. We accept varied payment terms tailored for your convenience and provide packaging that matches the customizable length and size requirements. Relish a smooth procurement experience with exceptional service from order to delivery.


FAQ's of HPT Power-Limiting Heating Cable:


Q: How is the HPT Power-Limiting Heating Cable installed for maximum efficiency?

A: The cable can be surface-mounted or pipe-wrapped, ensuring optimal thermal contact. Follow manufacturer guidelines for bend radius and installation temperature to guarantee safe and effective operation.

Q: What surfaces and media are suitable for using the HPT heating cable?

A: This cable is designed for versatile applications, functioning well on metal or plastic pipes, tanks, and exposed surfaces. It's compatible with water, oils, acids, alkalis, and solvents.

Q: Where can I use this cable in hazardous locations?

A: The cable's explosion-proof rating and compliance with international standards make it ideal for hazardous locations such as industrial plants, refineries, and chemical processing facilities.

Q: When should I choose power-limiting cables over other heating options?

A: Power-limiting cables are preferable when precise temperature regulation, energy efficiency, and safety in hazardous or outdoor settings are essential. They offer excellent protection against freezing or overheating.

Q: What is the process for ordering customized cables?

A: Simply specify the desired length, voltage, and other requirements. Upon order completion, the product will be packaged and either dropped off or handed over, ready for immediate installation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Heat Trace Cable Category

FP Parallel Constant Watt Heating Cable

FP Parallel Constant Watt Heating Cable

Price 50000 INR / Meter

Minimum Order Quantity : 5

Product Type : Parallel Constant Watt Heating Cable

Insulation : Crosslinked polyolefin or fluoropolymer

Size : Varies (4mm to 12mm diameter typically)

Jacket Material : Other, Fluoropolymer, Polyolefin, Thermoplastic

VSX Self-Regulating Heat Cable

VSX Self-Regulating Heat Cable

Price 1000 INR / Meter

Minimum Order Quantity : 5

Product Type : Selfregulating heat trace cable

Insulation : Thermoplastic elastomer (TPE) or Fluoropolymer

Size : Varies (typical crosssection width 1216mm, height 57mm)

Jacket Material : Other, Polyolefin or fluoropolymer (standard jacket: thermoplastic, optional fluoropolymer for harsh environments)

HTEK Series Constant Watt Heating Cable

HTEK Series Constant Watt Heating Cable

Price 1000 INR

Minimum Order Quantity : 5

Product Type : Constant Watt Heating Cable

Insulation : High temperature resistant Fluoropolymer

Size : As per design specification

Jacket Material : Other, Polyolefin / Fluoropolymer

FLX Self-Regulating Heating Cable

FLX Self-Regulating Heating Cable

Minimum Order Quantity : 5

Product Type : SelfRegulating Heating Cable

Insulation : Polyolefin Primary Insulation

Size : Standard sizes available, customizable

Jacket Material : Other, Thermoplastic, Polyolefin, or Fluoropolymer



arrow