DLX Self-Regulating Heating Cable
DLX Self-Regulating Heating Cable

DLX Self-Regulating Heating Cable

DLX Self-Regulating Heating Cable Specification

  • Core Material
  • Copper
  • Number of Conductor
  • 2
  • Usage & Applications
  • Hot water maintenance, gutter & roof de-icing, industrial pipeline heat tracing
  • Core Number
  • 2
  • Install Type
  • Directly on pipes/tanks, under floors, on roofs/gutters
  • Rated Temperature
  • Up to 65C (continuous), exposure up to 85C
  • Armored Material
  • Tinned copper (optional)
  • Tensile Strength
  • High, designed for industrial use
  • Dielectiric Strength
  • 2000V AC/min
  • Conductor Shape
  • Stranded
  • Conductor Type
  • Parallel conductors
  • Features
  • Self-regulating, Flexible, Cut-to-length, Energy efficient, Safe for hazardous locations
  • Insulation
  • PTFE or Modified Polyolefin
  • Diameter
  • Approx. 6-13 mm (depends on type)
  • Impedance
  • Low; varies as self-regulating
  • Operating Temperature
  • -40C to 85C
  • Weight
  • Approx. 0.1-0.2 kg/m (depending on model)
  • Cable Type
  • Self-Regulating Heating Cable
  • Product Type
  • Heating Cable
  • Length
  • Customizable as per requirement
  • Voltage
  • 110V/220V/240V
  • Insulation Material
  • Other
  • Application
  • Other
  • Conductor Material
  • Tinned copper or nickel-plated copper
  • Jacket Material
  • UV-resistant thermoplastic or Fluoropolymer
  • Storage Temperature
  • -40C to +85C
  • Connector Color
  • Varies, typically black or gray
  • Shield Material
  • Tinned copper braid
  • Jacket Color
  • Other
  • Dimension (L*W*H)
  • Varies by length and model, typically 6-13 mm width
  • Material
  • Polyolefin, Copper, Fluoropolymer (as applicable)
  • Color
  • Gray/Black (outer jacket)
  • Size
  • Standard cross section 6 mm x 11 mm or 8 mm x 13 mm
  • Fire Resistance
  • Complies with IEC 60332-1
  • Maximum Circuit Length
  • Up to 100 meters (depending on cable rating & voltage)
  • Power Output
  • 10-60 W/m at 10C
  • Max Exposure Temperature (Power Off)
  • 120C
  • Minimum Bend Radius
  • 25 mm
  • Resistance per Meter
  • 10-60 ohms/km (varies by rating)
 

DLX Self-Regulating Heating Cable Trade Information

  • Minimum Order Quantity
  • 5 Meter
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10 Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About DLX Self-Regulating Heating Cable



Capitalise on the paragon of heating solutions with DL Self-Regulating Heating Cable-a first-rate innovation renowned for reliability and energy efficiency. This hot deal is engineered to meet demanding industrial standards, supporting maximum circuit lengths up to 100 meters and a power output of 10-60 W/m. Designed for flexibility and safety, the cable boasts fire resistance per IEC 60332-1 and operates efficiently from -40C to 85C. Order today and experience superior performance in hot water maintenance, de-icing, and industrial heat tracing. Custom lengths and voltage ratings available for a tailored solution.

DL Self-Regulating Heating Cable: Diverse Commercial Applications

Ideally suited for hot water maintenance, industrial pipeline heat tracing, floor heating, and roof or gutter de-icing, DL Self-Regulating Heating Cable excels in commercial environments. Install directly on pipes, tanks, or beneath flooring. Its flexible, cut-to-length design simplifies application in both new builds and retrofits. Simply attach the cable securely along the required surface, ensuring proper spacing and outlet connections, to benefit from efficient, automatic temperature regulation.


FOB Port, Supply Ability, and Payment Terms for DL Heating Cables

Our renowned DL Self-Regulating Heating Cables present exceptional market value, ready for prompt freight from major Indian FOB ports. We confidently supply high-volume shipped goods, catering to bulk requirements with reliable turnaround times. Multiple payment terms are facilitated for buyer convenience, ensuring a seamless procurement process. With robust supply ability, secure logistics, and flexible financial arrangements, your order is handled with first-rate professionalism.


FAQ's of DL Self-Regulating Heating Cable:


Q: How does the DL Self-Regulating Heating Cable adjust its power output during use?

A: The cable intelligently alters its power output based on ambient temperature, ensuring optimal energy use and preventing overheating. This self-regulation adapts performance to local conditions for safety and efficiency.

Q: What are the recommended commercial applications for this heating cable?

A: It is expertly designed for pipe freeze protection, hot water maintenance, roof and gutter de-icing, floor heating, and tank heating in industrial and commercial settings.

Q: Where should the DL Self-Regulating Heating Cable be installed?

A: Install the cable directly along pipes, tanks, rooftops, gutters, or beneath floors. It is cut-to-length for customized installations in various locations, indoors or outdoors.

Q: What is the process for ordering DL Self-Regulating Heating Cable?

A: Simply contact your supplier or trader, specify your length, voltage, and insulation preferences, and arrange payment terms. The goods will be shipped from leading Indian FOB ports.

Q: What benefits does the cable's self-regulating feature provide?

A: This feature maximizes energy efficiency, offers safety for use in hazardous locations, and delivers consistent heat without the risk of overheating.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Heat Trace Cable Category

FPX Parallel Constant Watt Heating Cable

FPX Parallel Constant Watt Heating Cable

Price 50000 INR / Meter

Minimum Order Quantity : 5

Application : Other

Storage Temperature : 40C to +60C

Cable Type : Parallel Constant Watt Heating Cable

Weight : Varies by length and model

VS Self-Regulating Heat Cable

VS Self-Regulating Heat Cable

Price 1000 INR / Meter

Minimum Order Quantity : 5

Application : Other, Pipe tracing, freeze protection, roof and gutter deicing, tank heating, process temperature maintenance

Storage Temperature : 40C to 85C

Cable Type : Selfregulating heating cable

Weight : Varies by length (approx. 0.12 kg/m)

BSX Self-Regulating Heating Cable

BSX Self-Regulating Heating Cable

Price 50000 INR / Meter

Minimum Order Quantity : 5

Application : Other

Storage Temperature : 40C to +85C

Cable Type : Selfregulating heating cable

Weight : Varies with length and type

FLX Self-Regulating Heating Cable

FLX Self-Regulating Heating Cable

Minimum Order Quantity : 5

Application : Other

Storage Temperature : 40C to +85C

Cable Type : Flexible Parallel Heating Cable

Weight : Varies by length and type



arrow